Customization: | Available |
---|---|
Theory: | Latching Relay |
Usage: | Electricity Meter |
Still deciding? Get samples of US$ 1.0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Three phase Polarized latching relay TP41-16A, with continuous switching current capability up to 120A. The relay coil can be designed to single winding and double winding with coil voltage from 5VDC to 48VDC. The advantage of polarized latching relays is the pulse driven operation of some milliseconds, coil heating can be neglected. The relay is designed and manufactured in accordance to IEC 61810-1 as well as meet the requirements of IEC 62055-31.
1. Three phase 120A switching capability;
2. Both Single coil and double coil can be customized, the coil rated voltage can be 5VDC-48VDC;
3. Multi-layer blades, low temperature rise;
4. Silver alloy contacts materials AgSnO2, with reliable electrical endurance;
5. Conform to IEC 62055-31 UC3 Rating;
6. Outline dimension:120mm×54mm×29.5mm;
7. Environmental protection (comply with ROSH) ;
8. Cost Efficiency.
Coil data
Rated Coil voltage |
6VDC, 9VDC, 12VDC, 24VDC, 48VDC |
Single coil power |
2.5 W |
Double coil power |
5 W |
Pulse width |
50ms Max |
Pulse time |
<50 ms (At rated voltage) |
Contact data
Contact materials |
AgSnO2 |
Contact arrangement |
3 A(B) |
Contact resistance |
1.0 mΩ Max(Test under 1A/6VDC) |
Max switching current |
120 A |
Max switching voltage |
253 VAC |
Max switching power |
30000VA |
Mechanical life |
1×105 OPS |
Electrical life |
1×104 OPS |
Standard winding(Coil voltage can be customized)
Rated coil voltage(VDC) |
Max operating voltage(VDC) |
Coil resistance (1±10%)(Ω)
|
Single winding |
||
6 |
4.8 |
14.4 |
9 |
817.2 |
32.4 |
12 |
9.6 |
57.6 |
24 |
19.2 |
230.4 |
48 |
38.4 |
921.60 |
Double winding |
||
6 |
4.8 |
7.2+7.2 |
9 |
7.2 |
16.2+16.2 |
12 |
9.6 |
28.8+28.8 |
24 |
19.2 |
115.2+115.2 |
48 |
38.4 |
460.8+460.8 |
Insulation resistance |
1000MΩ |
Dielectric strength between coil |
4000V 1 minute |
Dielectric strength between contact |
2000V 1 minute |
Creepage distance |
8mm |
Shock resistance |
147m/S2 |
Vibration resistance |
10-55HZ amplitude 1.5mm |
Ambient temperature |
-40-+85ºC |
Weight |
Approx.300g |
Construction |
Dust protection |
UC Class |
Voltage (UC) |
Current (IC) | Power factor |
Close/ open time (S) |
Electrical endurance (OPS) |
UC3 |
220 VAC |
100 A |
cosφ=1.0
cosφ=0.5 |
10: 20 |
5000 Cycle 10000 Cycle 5000 Cycle |
Outline dimensions and circuit diagram